Hydranal Coulomat AK Honeywell Specification

  • Accuracy
  • +/- 0.5 %
  • Power Supply
  • Electric
  • Features
  • Temperature Control,Digital Display,Energy Regulator
  • Usage
  • Industrial
  • Color
  • Multicolor
  • Halogen Content
  • Halogen-free
  • Hydranal Grade
  • Coulomat AK
  • Storage Temperature
  • Store at room temp.
  • Form
  • Liquid
  • Titration Range
  • Low to high levels
  • Bottle Type
  • Amber glass
  • Shelf Life
  • 12 months
  • Solvent Base
  • Alcoholic
 

Hydranal Coulomat AK Honeywell Trade Information

  • Minimum Order Quantity
  • 1 Bottle
  • FOB Port
  • JAIPUR
  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Telegraphic Transfer (T/T)
  • Supply Ability
  • 100 Bottles Per Day
  • Delivery Time
  • 7 Days
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Main Export Market(s)
  • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
  • Main Domestic Market
  • All India
 

About Hydranal Coulomat AK Honeywell

Honeywell HYDRANAL-Coulomat AK is a reagent used for coulometric Karl Fischer titration, specifically in ketone-based samples where a methanol-free solution is preferred, according to Honeywell Research Chemicals. It's designed for use in cells with a diaphragm. The reagent can develop trace amounts of iodine during storage, indicated by a brown color, which can be removed by exposure to humid air before use. Here's a more detailed breakdown:
  • Coulometric Karl Fischer Titration:This method is used to determine the water content in various samples, including those containing ketones. 
  • Anolyte:HYDRANAL-Coulomat AK is an anolyte, meaning it's the solution used in the anodic (positive) compartment of the titration cell. 
  • Ketone Compatibility:It's specifically designed to be used in samples containing ketones, where a methanol-free solution is preferred to avoid potential side reactions. 
  • Diaphragm Cells:It's designed for use in titration cells that include a diaphragm, a physical barrier separating the anodic and cathodic compartments. 
  • Iodine Formation:During storage, the reagent can form trace amounts of free iodine, which is indicated by a light brown color. 
  • Iodine Reduction:This iodine can be removed by exposing the opened bottle to humid air before use. 
  • Suitability Test:A suitability test is often performed to ensure the reagent is appropriate for the specific Karl Fischer titration being conducted. 


Versatile Titration Capability

Hydranal Coulomat AK provides exceptional flexibility for varying analytical needs, covering both low and high water content measurements. Its accuracy and precision make it reliable for demanding industrial applications where different titration ranges are required. This versatility simplifies procurement and inventory management by serving multiple testing protocols.


Safe and Convenient Storage

Packaged in sturdy amber glass bottles, Hydranal Coulomat AK retains its integrity when stored at room temperature. The recommended shelf life of 12 months ensures consistent quality, while its halogen-free formulation minimizes environmental and process-related risks. Multicolor labeling further aids in easy identification during use.


Advanced Operating Features

Integrated temperature control, digital display, and an energy regulator provide optimal working conditions during titration. These advanced features help laboratories achieve consistent results and operational efficiency. Electric power supply supports uninterrupted processes, making this reagent suitable for continuous industrial usage.

FAQ's of Hydranal Coulomat AK Honeywell:


Q: How should Hydranal Coulomat AK be stored to maintain its shelf life?

A: Hydranal Coulomat AK should be stored in its amber glass bottle at room temperature to ensure it remains stable and effective for the full 12-month shelf life. Avoid exposure to direct sunlight and drastic temperature changes.

Q: What is the process for using Hydranal Coulomat AK in Karl Fischer titration?

A: To use Hydranal Coulomat AK, introduce the liquid reagent to the titration cell, calibrate temperature control and energy regulation features, and perform the titration. The digital display aids in monitoring accuracy, which stands at +/- 0.5%, for both low and high-level measurements.

Q: Where can Hydranal Coulomat AK be sourced in India?

A: Hydranal Coulomat AK is available through several channels, including distributors, exporters, manufacturers, suppliers, and traders throughout India. Contact your preferred vendor to obtain the product for industrial applications.

Q: When is it recommended to replace the Hydranal Coulomat AK reagent?

A: It is advisable to replace Hydranal Coulomat AK after 12 months from the date of receipt, as this duration marks its recommended shelf life. Also, if any signs of degradation appear before this period, immediate replacement is suggested.

Q: What benefits does the halogen-free formulation of Hydranal Coulomat AK offer?

A: Being halogen-free, Hydranal Coulomat AK reduces the risk of unwanted side reactions and is safer for laboratory personnel and the environment. This makes it suitable for sensitive industrial operations requiring increased safety measures.

Q: How does the temperature control feature enhance the titration process with Hydranal Coulomat AK?

A: Temperature control ensures that the reagent maintains optimum reactive conditions during titration, resulting in more consistent and accurate readings, as well as improved reliability even under varying laboratory ambient temperatures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Honeywell Laboratory Reagent Category

HYDRANAL Coulomat CG-K

HYDRANAL Coulomat CG-K

Price 26217 INR / Piece

Minimum Order Quantity : 1 Piece

Color : Multocolor

Power Supply : Manual

Features : Temperature Control,Digital Display,Energy Regulator

Usage : Laboratory

Hydranal Coulomat A

Hydranal Coulomat A

Price 12500 INR / Bottle

Minimum Order Quantity : 1 Bottle

Color : m

Power Supply : Manual

Features : Temperature Control,Digital Display,Energy Regulator

Usage : Laboratory

HYDRANAL Coulomat CG

HYDRANAL Coulomat CG

Price 14500 INR / Bottle

Minimum Order Quantity : 1 Bottle

Color : Multocolor

Power Supply : Manual

Features : Insulated,Verical Orientation,Level/Pressure Indicator

Usage : Industrial

Acetic Acid Honeywell

Acetic Acid Honeywell

Price 15000 INR / Piece

Minimum Order Quantity : 1 Piece



Back to top